In most homes, yes. Changing from a system boiler to a combi boiler is one of the things we’re asked about most when people get in touch about a boiler replacement. Usually it’s because the cylinder is taking up the whole hot press and they’d like the space back, or because they’re tired of waiting for a tank of water to heat up, prompting them to consider a combi boiler conversion. It’s a common conversion in Dublin houses and it generally works out well, but there’s more to it than fitting a new boiler of the same type, and it isn’t the right choice for every household.

The same applies if you have an older conventional boiler, sometimes called a regular or heat-only boiler, with tanks in the attic. You can still go to a combi, there’s just a bit more work involved. Below we go through what changes, what we check before recommending a combi, and the situations where we’d tell you to stay with what you have.

System, conventional or combi: which one have you got?

It helps to know what you’re starting with, and a lot of people aren’t sure.

A conventional boiler is the older setup you’ll find in a lot of Irish houses built before the 2000s. There’s a cold water storage tank in the attic, usually with a smaller feed and expansion tank beside it for the heating, and a copper hot water cylinder in the hot press, normally with an immersion. The boiler heats both the radiators and the cylinder, and most of the taps in the house are fed by gravity from the tank in the attic.

A system boiler does away with the small feed and expansion tank. The pump and expansion vessel are built into the boiler itself and the heating runs as a sealed, pressurised system, which is why there’s a pressure gauge on the front of the boiler, ensuring optimal mains water pressure for the modern combi boiler. It still heats a cylinder, which could be a vented one fed from the attic or an unvented one that runs off the mains.

A combi heats your radiators and gives you hot water straight from the mains as soon as you turn on a tap. There’s no cylinder and, in most cases, no tanks in the attic either.

So if there’s a cylinder in the hot press and a pressure gauge on the boiler, it’s most likely a system boiler. If there’s a cylinder and two tanks in the attic, it’s probably conventional. Going from either one to a combi means taking the cylinder out of the picture, and that’s where most of the work comes from in the combi boiler conversion process.

Combi boiler conversion – Is your water pressure good enough for a combi?

This is the first thing we check, because a combi is only as good as the water supply coming into the house.

With a cylinder, your hot water is heated in advance and stored until you need it. A combi has nothing stored. It takes cold water straight off the mains and heats it as it passes through, so the flow you get at the hot tap depends on how much water the mains can deliver and how quickly the boiler can heat it.

During the survey we measure the flow and pressure at the kitchen tap, which is normally the first tap on the mains. As a rough guide, we like to see a flow rate of around 10 to 12 litres a minute or more, with the pressure staying at about 1 bar or above while the tap is running, which is essential for a modern combi boiler. A house can have decent pressure with the tap turned off and still struggle once water is actually flowing, so the running figure is the one that counts.

Older houses sometimes have a narrow or lead supply pipe coming in from the road, which can hold the flow back. Lead pipes are worth replacing anyway, and upgrading the supply can make a combi workable in a house where it otherwise wouldn’t be. Pressure can also vary depending on the area and the time of day, so if yours is noticeably weak first thing in the morning, let us know.

What happens to the cylinder and attic tanks

Once the combi is in, the cylinder isn’t needed any more, so it comes out along with the immersion. Most people are glad to see the back of it. You get the hot press back for storage, and there’s no more switching on the immersion or waiting for the water to heat.

Something people don’t always think about is that the hot press won’t be warm anymore. If you’ve always used it for airing clothes, that stops once the cylinder is gone.

Up in the attic, the feed and expansion tank for the heating can be removed, as the heating becomes a sealed system. The main cold water tank may or may not go, especially if you’re considering an upgrade to a combi boiler. If all your cold taps and toilets are moved over to the mains, it can be taken out, which frees up space in the attic and means one less tank that could leak or freeze. In some houses, it makes more sense to leave it feeding the toilets for now, and we’ll go through the options with you. Either way, we take care of the removal, cap off the old pipes and take everything away with us. If you’re keeping the tank and it’s an old one, our upgrade to a combi boiler consultation will help you decide. attic water tank replacement page has more on when they need changing.

Switch to a combi boiler – Pipework and other changes

This is the part that makes a conversion take longer than a straight boiler swap.

At the moment, hot water leaves the cylinder in the hot press and travels to the taps. With a combi, it comes from the boiler, so the hot supply has to be re-routed from wherever the new boiler is going to sit. If the boiler is in the kitchen and your main bathroom is at the far end of the house, you’ll wait a little longer for the hot water to come through, so the boiler’s position is worth some thought. Some people move it into the old hot press, closer to the bathroom, if a flue can be run out from there.

The gas supply often needs looking at too. A combi has to heat water very quickly, so it burns gas at a higher rate than a system boiler when a hot tap is on. The existing gas pipe from the meter is sometimes too small to keep up and has to be upsized. We check this at the survey so it’s included in your quote.

If you’re coming from a conventional boiler, the heating changes from an open-vented system to a sealed, pressurised one, making the change to a combi boiler more efficient. Old radiators, valves and joints that were fine at low pressure can start to weep once the system is pressurised, so we pressure test it and look for weak spots. If you already have a system boiler, the heating is sealed already, and this isn’t an issue when considering a change to a combi boiler.

A new boiler also shouldn’t be connected to old, dirty system water. Every NRM boiler installation includes a system cleanse and a magnetic filter, and if the radiators are badly sludged up we’ll recommend a power flush before the new boiler goes on.

Finally, like any modern condensing boiler, a combi needs a flue to the outside and a condensate pipe running to a drain. If the boiler stays in the same spot, this is usually straightforward. Moving it can mean a new flue position and a longer condensate run.

Upgrade to a combi boiler - Can You Replace a System Boiler with a Combi Boiler in Dublin

What it means for your showers

Showers are where a lot of Irish homes need a bit of extra thought.

If your showers are electric, which is very common here, they won’t be affected. An electric shower heats its own water from the cold mains and works the same whether you have a combi or a cylinder.

Pumped showers are a different matter. If you have a power shower, or a shower pump boosting water from the cylinder and attic tank, it will have to come out. A shower pump can’t be connected to the mains supply, and with a combi there’s no stored water for it to draw from anyway. A combi on a decent mains supply will usually give you a good strong shower without a pump, although it may feel a bit different to what you’re used to.

Mixer showers and taps work best when the hot and cold supplies are at similar pressures. If the hot water is coming from a combi at mains pressure and the cold is still coming from the attic tank, you can end up with a shower that swings between too hot and too cold. For that reason, the cold supply to the showers is usually moved over to the mains at the same time.

Does a combi suit a house with more than one bathroom?

This is usually the deciding factor, and the honest answer is that it depends on how the bathrooms get used.

A combi can only heat so much water at once. As a rough idea, a 24kW combi gives you about 10 litres of hot water a minute, a 30kW model about 12 litres and a 35kW model about 14 litres, based on the water being heated by around 35°C. In the middle of winter, when the water coming in from the mains is colder, the boiler has more work to do, and the flow rate drops a little, affecting the efficiency of the water-on-demand system. A decent mixer shower uses somewhere in the region of 8 to 12 litres a minute.

That means a combi will run one shower well. Run two showers at the same time, or a shower while someone is filling the bath or using the kitchen tap, and the hot water gets split between them. Both get weaker, and the temperature can wander.

In a house with one bathroom, a combi is usually a very good fit. A main bathroom plus an en suite can work fine too, especially if one of the showers is electric or people aren’t usually showering at the same time. Where we’d be more cautious is a house with two or three bathrooms that are all in use in the morning, a busy family home, or a house where people like a big deep bath. In those homes, a system boiler with a good unvented cylinder will normally give a better result, because there’s a full tank of hot water ready to go. If that sounds more like your house, our hot water cylinder replacement page covers the options.

When it’s better to stay with a system boiler

Apart from the bathroom question, there are a few other situations where we’d usually advise against switching.

If the mains flow into the house is poor and can’t easily be improved, a combi will be a disappointment, particularly in the shower. If you have solar thermal panels on the roof heating your cylinder, taking the cylinder out means losing the benefit of them. Some people also like having the immersion as a backup. With a cylinder, if the boiler breaks down, you can still get hot water from the immersion while you wait for a repair. With a combi, no boiler means no hot water until it’s fixed.

Think too about where your heating might be heading over the next few years. A heat pump needs a hot water cylinder, so if you think you might switch to one, removing the cylinder now and giving the hot press over to storage can make that change harder later. SEAI grants for heat pumps now go up to €14,500 for a house, while there’s no grant at all for a gas boiler. If you’d like to weigh up that option as well, our Heat Pumps Ireland page has more information.

None of this means a combi is a bad choice. It just isn’t the right one for every house, and we’d rather tell you that before any work starts.

How much does it cost and how long does it take?

A new combi boiler from NRM typically costs between €4,800 and €6,200 supplied and fitted. That includes the boiler and flue, a standard installation, basic controls, a system cleanse, a magnetic filter and a handover so you know how everything works. The final price depends mainly on the boiler model and output, the route the flue takes and the controls you go for.

A conversion from a system or conventional boiler can involve work that a straight replacement doesn’t, such as removing the cylinder and tanks, re-routing hot water pipes or upsizing the gas pipe. Anything like that is priced into your quote after the survey, so there are no surprises on the day. If a power flush is needed, it’s an extra €750.

A like-for-like boiler swap is usually done in a day. A conversion to a combi normally takes two to three days, depending on how much pipework is involved. You’ll be without heating and hot water for part of that time, and we’ll let you know in advance when that will be.

We fit Worcester Bosch, Viessmann and Ideal boilers. Depending on the brand and model, the manufacturer’s warranty runs from 2 up to 12 years, on top of our own 12-month warranty on the workmanship.

If you’d like a rough figure before booking a survey, our gas boiler replacement estimator will give you a guide price in a couple of minutes.

Grants, certificates and regulations

SEAI doesn’t give grants for gas boilers, so there’s nothing towards the modern combi boiler itself. The one grant that sometimes comes into it is the SEAI heating controls grant of €700, which is for upgrading the controls on your heating system. It’s for homes built and occupied before 2011; you need grant approval before the work starts, and it has to be carried out by an SEAI-registered contractor. Whether you qualify depends on the controls being fitted, so we’ll tell you at the quote stage. There’s more detail on our page about applying for the heating controls grant.

All gas work in Ireland has to be carried out by a Registered Gas Installer, and NRM is RGII registered. Once the job is finished, you should get a certificate for the gas installation. Keep it with your house documents, as a buyer’s solicitor may ask for it if you ever sell. New boilers also have to be high-efficiency condensing models to meet the building regulations, which every boiler we fit is.

How a combi conversion works with NRM

  1. Survey. We look at your current boiler, cylinder and tanks, test the mains flow and pressure at the kitchen tap, check the size of the gas pipe and work out where the new boiler and flue will go.
  2. Recommendation. Based on what we find and how your household uses hot water, we’ll tell you whether a combi boiler could be the right move or whether you’d be better off with a new system boiler.
  3. Written quote for the combi boiler conversion. You get a price covering the boiler, any pipework changes and the removal of the cylinder and tanks.
  4. Installation. We drain down the system, take out the old boiler, cylinder and tanks, make the pipework changes, clean the system and fit the new combi with a magnetic filter.
  5. Commissioning and handover. The boiler is tested and commissioned, we show you how to use the controls, and you get your gas certificate and warranty details.

We install boilers right across Dublin. For more on the boilers we fit and what’s included, see our gas boiler replacement page, or call us on 087 990 89 13 to arrange a survey.

System Boiler to Combi Boiler - NRM Dublin's Upgrade Guide

System boiler to combi boiler: quick FAQ

Can I change from a system boiler to a combi boiler for better flow rate and water on demand?
Yes, in most homes, as long as the mains flow and pressure are good enough and the house doesn’t need a lot of hot water at the same time. The cylinder is removed and the hot water pipes are re-routed to the new boiler.

Will a combi boiler work with low water pressure?
Not well, especially if you’re relying on outdated systems instead of a modern combi boiler for water on demand. A combi takes its hot water straight from the mains, so if the flow coming into the house is weak, your showers and taps will be too. We test the flow before recommending one.

Is a combi boiler OK for two bathrooms?
It can be, if the showers aren’t usually used at the same time or one of them is electric. For two or more bathrooms that are regularly in use together, a system boiler with an unvented cylinder is usually the better option.

Do the tanks in the attic have to go?
The feed and expansion tank for the heating is no longer needed and comes out. The main cold water tank can go too if all the cold supplies are moved to the mains, but that isn’t always necessary.

How long does a system to combi conversion take?
Usually two to three days, compared with about a day for a like-for-like boiler replacement.

Is there a grant for a new combi boiler?
No. SEAI doesn’t grant-aid gas boilers. The €700 heating controls grant may apply to the controls in some cases, and we’ll let you know if it does.